Designed for the detection of explosive gases, toxic gases or oxygen, this detector comes with a Wheatstone bridge output (OLC 100) or 4-20mA output (OLCT 100). Whatever your application Oldham offers a solutions: catalytic, electrochemical, semiconductor, or poison control version. ATEX approved, these detectors are available in explosion safe or intrinsically safe versions. In addition to this range the OLC/OLCT 100 offers an infrared sensor, which allows it to be used in more severe environmental conditions, where the presence of poisons could harm the use of a catalytic sensor. With a 3-year warranty on the sensor and electronics, the OLCT 100 XP-IR will provide reliability and extended lifetime. With this new line of detectors, Oldham broadens its product range with products that combine reliability, durability and ease of use.
SIL 2 certified according to EN 50402, the 100 series is very safe. As an example the Probability of Failure on Demand (PFD) of combustible versions is 1 out of 418 for the catalytic version and 1 out of 2857 for the infrared version.
OLCT 100 XP: Explosion-proof version and equipped with a catalytic, electrochemical or semiconductor sensor, for detection of explosive, toxic gases or oxygen.
OLCT 100 IS: Intrinsically safe version and equipped with an electrochemical sensor for detection of toxic gases or oxygen.
OLCT 100 XP IR: Explosion-proof version and equipped with an infrared sensor for detection of explosive gases or CO2.
OLCT 100 XP HT: High temperature explosion-proof version, for detection of explosive gases up to 200°C.
Technical Specifications
Model |
OLC 100 |
OLCT 100 XP |
OLCT 100 XP IR |
OLCT 100 XP |
OLCT 100 XP HT |
OLCT 100 XP |
OLCT 100 IS |
Sensor
|
Catalytic bead
|
Catalytic bead
|
Infrared
|
Electrochemical
|
Catalytic bead
|
Semi-conductor
|
Electrochemical
|
Material |
Epoxy-coated aluminum housing (Inox 316L optional)
316 stainless steel sensors |
Dimensions (mm) (inches) |
138 x 133 x 84
5.43 x 5.24 x 3.31" 138 x 133 x 84
5.43 x 5.24 x 3.31" |
179 x 138 x 84
7.05 x 5.43 x 3.31" |
179 x 138 x 84
7.05 x 5.43 x 3.31" |
150 x 138 x 84
5.91 x 5.43 x 3.31" |
179 x 138 x 84
7.05 x 5.43 x 3.31" |
179 x 138 x 84
7.05 x 5.43 x 3.31" |
Weight (kg) |
0.95 |
1 |
1.1 |
1.1 |
1.8 |
1.1 |
1.1 |
Ingress Protection |
IP66 |
Cable Entry |
M20 or ¾ NPT |
Supply Voltage |
only by OLDHAM Controller |
15.5 to 32 VDC |
13.5 to 32 VDC |
10 to 32 VDC |
15.5 to 32 VDC |
15.5 to 32 VDC |
15.5 to 32 VDC |
Average Consumption |
340 mA |
110 mA |
80 mA |
23.5 mA |
100 mA |
100 mA |
23.5 mA |
Pressure |
atmospheric ± 10%
|
Output signal |
Usual source encoded from 0 to 23 mA (not isolated)
- linear 4 to 20 mA output, reserved for measurement
- 0 mA : electronic fault or no power supply
- < 1 mA: fault
- 2 mA: initialization mode
- > 23 mA: out of range
|
Approvals |
Compliant with European directive ATEX 94/9/CE and with IECEx schedule for explosion-proof detectors. OLC 100, OLCT 100 XP, OLCT 100 XP IR: ATEX II 2 GD / Ex d IIC T6 Gb / Ex t IIIC T85°C Db IP66
OLCT 100 IS Aluminum: ATEX II 2 GD / Ex ia IIC T4 / Ex iaD 21 T135°C IP66
OLCT 100 IS Stainless Steel: ATEX II 1 GD / Ex ia IIC T4 / Ex iaD 20 T135°C IP66
SIL 2 according to EN 50402 / EN 61508 for catalytic and infrared versions, O2, CO, NH3 and H2S Metrological performances according to EN/IEC 60079-29-1
Electromagnetic compatibility according to EN 50270 |
Cable |
3 active wires,
shielded cable |
3 active wires,
shielded cable |
3 active wires,
shielded cable |
2 active wires,
shielded cable |
3 active wires,
shielded cable |
3 active wires,
shielded cable |
2 active wires,
shielded cable |
|