SPECIFICATIONS
|
INSTRUMENT WARRANTY:
Two- year warranty, including sensors and battery
|
CASE MATERIALS:
Polycarbonate w/ protective rubber overmold
|
DIMENSIONS:
103 mm x 58 mm x 30 mm (4.1” x 2.3” x 1.2”) - Ventis lithium-ion battery
version
172 mm x 67 mm x 66 mm (6.8” x 2.6” x 2.6”) - Ventis with pump
lithium-ion battery version
|
WEIGHT:
182 g (6.4 oz) - Ventis, lithium-ion battery version
380 g (13.4 oz) - Ventis with Pump, lithium-ion battery version
|
Operating TEMPERATURE RANGE:
-20°C- 50°C (-4°F-122°F)
|
OPERATING HUMIDITY RANGE:
15%-95% Non-condensing (continuous)
|
DISPLAY:
Backlit Liquid Crystal Display (LCD)
|
POWER SOURCE/RUN TIME:
Rechargeable lithium-ion battery pack
(12 hours typical @ 20ºC) - Ventis
Rechargeable extended-range lithium-ion battery pack
(20 hours typical @ 20ºC) - Ventis
(12 hours typical @ 20ºC) - Ventis with pump
Replaceable AAA alkaline battery pack
(8 hours typical @ 20ºC) - Ventis
(4 hours typical @ 20ºC) - Ventis with pump
|
ALARMS:
Ultra-bright LEDs, loud audible alarm (95 dB at 30 cm), and vibrating alarm
|
SENSORS:
Combustible gases/methane - Catalytic Diffusion
O2, CO, H2S, NO2, SO2 - Electrochemical
|
SENSOR MEASURING RANGES:
Combustible Gases: 0-100% LEL in 1% increments
Methane (CH4): 0-5% of vol. in 0.01% increments
Oxygen (O2): 0-30% of vol. in 0.1% increments
Carbon monoxide (CO): 0-1,000 ppm in 1 ppm increments
Hydrogen sulfide (H2S): 0-500 ppm in 0.1 ppm increments
Nitrogen dioxide (NO2): 0-150 ppm in 0.1 ppm increments
Sulfur dioxide (SO2): 0-150 ppm in 0.1 ppm increments
|
CERTIFICATIONS:
|
UL:
|
Class I, Division 1, Groups A B C D, T4; Zone 0, AEx ia IIC T4
Class II, Groups F G (Carbonaceous & Grain dust);
IP66; IP67
|
ATEX:
|
Ex ia IIC T4 Ga and Ex ia I Ma;
Equipment Group and Category II 1G and I M1; IP66; IP67
|
IECEx:
|
Ex ia IIC T4 Ga; IP66; IP67
|
CSA:
|
Class I, Division 1, Groups A B C D, T4; Ex d ia IIC T4
C22.2 No. 152 for %LEL reading only
|
ANZEx:
|
Ex ia s Zone 0 I/IIC T4; IP66; IP67
|
INMETRO:
|
Ex d ia IIC T4 Gb; IP66; IP67
|
KOSHA:
|
Ex d ia IIC T4
|
MSHA:
|
30 CFR Part 22; Permissible for underground mines; Li-ion versions only |
PA-DEP:
|
Permissible for PA Bituminous Underground Mines |
China Ex:
|
Ex ia d IIC T4 Gb |
China CMC:
|
Metrology approval |
China MA:
|
Approved for underground mines; diffusion (without pump)
standard Alkaline version only |
GOST- K:
|
PBExdiaI X / 1ExdiaIICT4 X |
GOST-R:
|
PBExdiaI X / 1ExdiaIICT4 X |
|